12 Volt RS-5 Commercial System (Two Channel)
12Volt – Extra Heavy Duty Equipment
Input Voltage : | 12 Volt DC (Max 16Volts DC) |
Current Drawn under DRY Conditions : | < 0.009A |
Current Drawn under WET Conditions : | < 0.135A |
Current Drawn under Battery Low : | < 0.008A |
Ground : | (-) Negative |
Housing : | High Grade ABS Plastic |
Weight Complete : | Approx. 1.195 Kgs |
Number of Anodes | 6 - Extra Heavy Duty |
Output Voltage : | (+) 40 - 49 Volts |
24 Volt RS-5 Commercial System (Two Channel)
24Volt – Extra Heavy Duty Equipment
Input Voltage : | 24 Volt DC (Max 32Volts DC) |
Current Drawn under DRY Conditions : | < 0.012A |
Current Drawn under WET Conditions : | < 0.175A |
Current Drawn under Battery Low : | < 0.008A |
Ground : | (-) Negative |
Housing : | High Grade ABS Plastic |
Weight Complete : | Approx. 1.220 Kgs |
Number of Anodes | 6 – Extra Heavy Duty |
Output Voltage : | (+) 40 - 49 Volts |
RUSTSTOP® ELECTRONIC UNIT – WIRE SPECIFICATIONS
The cable supplied with each unit is generally more than sufficient, however for some larger vehicles some additional wire may occasionally be needed. If so please ensure that it is of the same specification supplied (as below):
Multi Strand Panel Flex wire
Size: 0.50mm² (0.75mm² can also be used)
Voltage Rating 500V
Nominal Current Rating 3A min
Strand No x Diameter: 14 x 0.21
Temp.range = –10 to +80 degrees C
Insulation: Flexible grade PVC
Flexibility class 4&5
Conductor type: High Conductivity annealed copper
In highly corrosive environment, and extreme temperature condition, (extreme conditions), we would suggest the use of corrosive resistant 0.75mm² Silicon wiring for the anodes.